057-254 ISSUE: 2
DEEP SEA ELECTRONICS PLC
DSE8610 MKII Operator Manual
Document Number: 057-254
Author: Mark Graham

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the DSE 8610 MKII and is the answer not in the manual?

Summary

2 Specification

3 Installation

4 Description of Controls

4.1 Control Push Buttons

Explains the function and operation of each push button on the module's front panel.

5 Operation

5.2 Stop;Reset Mode

Explains how to enter Stop/Reset mode and its implications for generator operation.

5.3 Manual Mode

Details manual operation, including starting sequences and engine running.

5.4 Automatic Mode

Describes automatic operation, including starting, running, and stopping sequences.

5.10 Dead Bus Synchronising (Auto Mode)

Explains the benefits, requirements, and operation of dead bus synchronising.

6 Protections

6.1 Alarms

Describes the alarm system, including types, causes, and display.

6.3 Warning Alarms

Details warning alarms that draw operator attention to undesirable conditions.

6.4 Electrical Trip Alarms

Describes electrical trip alarms that stop the generator in a controlled manner.

6.5 Shutdown Alarms

Details shutdown alarms that immediately stop the generator to prevent damage.

6.7 Over Current Alarm

Covers the over current alarm, including immediate warnings and IDMT curves.

6.8 Short Circuit IDMT Alarm

Details the short circuit IDMT alarm and its application for thermal protection.

6.9 Earth Fault IDMT Alarm

Explains the earth fault IDMT alarm for detecting earth fault currents.

7 Front Panel Configuration

7.1 Main Configuration Editor

Guides on accessing, entering PIN, editing, and exiting the main configuration editor.

7.2 ‘Running’ Configuration Editor

Details accessing and editing parameters while the generator is running.

8 Commissioning

8.2 DSE 4 Steps to Successful Synchronising

Details the four essential steps for achieving successful synchronisation.

9 Fault Finding

9.1 Starting Faults

Troubleshooting guide for starting issues, symptoms, and possible remedies.

9.2 Loading Faults

Troubleshooting guide for loading issues, symptoms, and possible remedies.

9.3 Alarms Faults

Troubleshooting guide for alarm issues, symptoms, and possible remedies.

DSE 8610 MKII Specifications

General IconGeneral
Generator & Mains Frequency3.5 Hz to 75 Hz
DisplayLCD with backlight
CommunicationRS232, RS485, Ethernet, USB
Inputs4 analogue inputs
OutputsConfigurable x 8
Power Supply8 to 35 V DC
Operating Temperature+70°C
Dimensions240mm x 181mm x 42mm
Magnetic Pick-up Voltage Range0.5 V
Magnetic Pick-up Frequency10, 000 Hz (max)
Protection RatingIP65 (Front only)