EasyManua.ls Logo

duagon MC50M - EMC, Electrical Safety, and Other Compliance; Reliability and BIOS;Boot Loader

duagon MC50M
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Overview
20MC50M00 E5
2020-10-20
19
EMC emission
- EN 50121-3-2:2016
- Regelung Nr. EMV 06 :2014-07-29, Anhang E: Messung an Geräten
EMC immunity: EN 50121-3-2:2016
Protective coatings: EN 50155:2017, class PC2 (Any PCB protected on both sides)
Useful life: 20 years (EN 50155:2017, class L4)
Product Compliance: Rail - Wayside Non-Safety Related
Operating temperature: -40 °C to +70 °C (EN 50125-3:2003, class T2, cubicle, with
class T2 maximum extended by 5 °C)
Storage temperature: -40 °C (EN 60068-2-1:2007, Ab) to +85 °C
(EN 60068-2-2:2007, Bb)
Altitude: +3000 m max. (EN 50125-3:2003, class AX)
Humidity: 100 % RH max. (EN 50125-2:2002, control cabinet, class T1/T2/TX)
Shock: 11 ms @ 20 m/s² (EN 50125-3:2003, in a switch cabinet 1 m to 3 m from the
track)
Vibration: 2.3 m/s² (EN 50125-3:2003, in a switch cabinet 1 m to 3 m from the track)
Electrical safety
- EN 50124-1:2017
- EN 62368-1:2014 + AC:2015
EMC emission
- EN 50121-4:2016
- EN 61000-6-4:2007 + A1:2011
EMC immunity
- EN 50121-4:2016
- EN 61000-6-2:2005
Restrictions: Service interfaces may only be used with a maximum cable length of
3 m for installations 10 m or less away from the track.
Product Compliance: Road Vehicle
EMC emission: ECE R10 Rev.5
EMC immunity: ECE R10 Rev.5
Reliability
421 000 h predicted @ 40 °C according to IEC/TR 62380 (RDF 2000)
BIOS/Boot Loader
AMI Aptio UEFI Firmware

Table of Contents