EasyManua.ls Logo

duagon MC50M - Inrush Current and Power Cable

duagon MC50M
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functional Description
20MC50M00 E5
2020-10-20
49
Figure 12. Ignition and shut-down delay watchdog state diagram
3.1.4 Inrush Current
To prevent damages to the MC50M due to exceeding inrush current, take the measured
inrush current values into account when designing your circuit protection.
Table 6. Inrush current measurements on PWR_IN
3.1.5 Power Cable
duagon offers a starter kit including a power cable (5-pin M12 to Euro plug).
Input Voltage Inrush Energy I²t
Inrush Current
(Peak)
16.8 V DC min. 0.042 A²s 27 A
24 V DC nom. 0.089 A²s 41 A
48 V DC nom. 0.353 A²s 82 A
60 V DC max. 0.507 A²s 98 A
See the duagon website for ordering information:
www.duagon.com/products/mc50m/#ord
Power:OFF
IGNITION:OFF
Power:ON
WDOG:OFF
IGNITION:ON
IGNITION:ON
Powerbutton:EVENT
WDOG:ON
Power:ON
IGNITION:OFF
PS_ON:OFF
WDOG:TIMEOUT
WDOG:RESET