Maintenance Manual for DUKE TSC Proofer
Oven with Touch Screen Controls
16
Figure 30: Opti-Mist Nozzle Filter
Clean Opti-Mist proofer nozzle screen.2.
Remove nozzle assembly by depressing latch
on quick-connect tting and pull nozzle out
toward fan blade.
Use 3/4" and 5/8" wrenches to remove nozzle
from body, remove, clean and re-install
lter.
Soak nozzle in plain white vinegar for 4-8 hours
to dissolve mineral deposits. Wipe residue
from nozzle and rinse in clean water.
Do not insert objects into nozzle outlet as this
can change the water spray performance.
Replace nozzle assembly if mineral deposits
from hard water cannot be removed.
Reinstall nozzle by inserting into quick-connect
tting until fully seated.