To activate the needle cooling in the software:
1. Log in as a technician.
User: technician
Password: 25483
The needle cooling has been preset in the software. Check anyway if
the set value is correct.
2. Open the menu Navigation > Settings >
Machine Configuration and press the
Input/Output Configuration button.
3. Press the Configuration of the outputs button.
4. Check in the section OUT04(A2.X28.2) (parameter t5730)
if the value is set to 1.
5. Press the button to exit the menu.
6. Open the menu Navigation > Settings >
Machine Configuration and press the Needle
Cooling button.
7. Select the ON setting.
Needle cooling is activated.
Press the button to return to the main screen.