Leaders in Pipeline Survey Systems
OPERATOR’S MANUAL
Issue 4.04 - 1207 38
Print Cnvrt
The key ‘Print cnvrt’ allows data to be paced correctly for a Patton electronics (www.patton.com)
model 2029 serial-to-parallel converter, for direct connection to a parallel printer. Use this key
when using the converter. DO NOT use the other keys. As a printer expects line-feeds, using
the other keys will print out on ONE line. NOTE: This interface is not guaranteed to work with
all printers, it is recommended to use DCAPP instead.
After download, the screen will revert to the startup screen.
C-SCAN 2010
The key C-SCAN 2010 allows data to be downloaded to DCAPP 2010. Note that DCAPP 2010
will accept any of the downloads selected. Start DCAPP 2010, connect C-SCAN and click the
DL button on DCAPP 2010, then press C-SCAN 2010 on the keypad.
After download, the screen will revert to the startup screen.
NOTE: DCAPP 2010 may not be supplied with your system. If this is the case, use DCAPP for
Excel.
NOTE: If after download, DCAPP reports ‘no data’ check your regional settings on your PC. The
decimal separator should be ‘.’ or ‘,’. Any other character will report ‘no data’.
See Survey Procedure Manual for more details on DCAPP.
Unlike C-SCAN 2000 systems, the data remains in memory and a new survey will continue from
the last survey point stored. The 2010 can store 500 survey points split over 100 surveys, so it
is unlikely that a surveyor will run out of memory.
However, it is recommended that the memory is cleared after successful download (unless a
survey is continuing). Note that pipeline details, diameter etc., will also be cleared.