Starting the engine
Set the forward/reverse lever (20) in neutral. The
engine can only be started with the lever in neutral.
Set the amplitude selector (13) for Low/High vibration to
mode O.
Set the revs control (16) to the idling mode.
Turn the starter switch (2) to mode I. Activate the
starter by turning the switch one position further.
Do not run the starter motor too long. If the
engine does not start immediately, wait a
minute or so before making a new attempt.
Warm up the diesel engine with the engine speed
control at the idling setting for a few minutes, or for a
longer period if the ambient air temperature is below
+10°C (+50°F).
Check while warming up that the warning lamps for oil
pressure (9) and charging (7) are out. The warning
lamp (8) for the parking brake shall still light.
When starting up and driving a cold machi-
ne, ie, cold hydraulic fluid, the braking
distance will be longer than normal until
the fluid reaches normal working tempera-
ture.
Ensure that ventilation (evacuation) is
adequate if the engine is run indoors. ie,
danger of carbon monoxide poisoning.
Fig. 15 Control panel
2. Starter switch
7. Charging lamp
8. Brake lamp
9. Oil pressure lamp/engine
temperature
13. Amplitude selector
16. Revs control
20. Forward/Reverse lever
789