5. It is highly recommended that a set of safety infra-red beams be used in conjuncon with this product. The safety beams must be
installed in such a way that the product is prevented from running when anything is in the path of the door or gate.
6. Over and above the recommendaon to use safety infra-red beams with this product it is mandatory to install and use a safety
beam set when using the automac closing feature. It is recommended that a warning light be ed to any automaon system.
7. The emergency manual release instrucon label must be installed on or adjacent to the emergency manual release mechanism.
Aer installaon - It is the responsibility of the installer to ensure the users:
1. Is procient in the use of the manual emergency release mechanism.
2. Is issued with the documentaon accompanying this product.
3. Understands that the gate or door may not be operated out of clear sight.
4. Ensures that children are kept clear of the gate or door area at all mes, and that children do not play with the remote transmiers
or any xed trigger switches linked to the system.
5. Is instructed not to aempt to repair or adjust the automaon system and to be aware of the danger of connuing to use the
automaon system in an unsafe condion before a service provider aends to it.
6. Is procient in tesng the unit’s safety obstrucon sensing system.
7. Is aware of what to check for with regards to wear and tear that may need to be aended to from me to me by the service
provider.
8. Is aware that a fagued baery may not be disposed of in the general refuse and must be handed in at a baery merchant for safe
disposal. Before removing the baery from the system the household mains must be disconnected. In the case of the motor unit
being removed and scrapped, the baery must be removed rst.
Technical specicaons.
Rated gate mass. 300kg
Maximum gate leaf length. 25m
Primary power supply to gate.
220 – 240Vac @ 50Hz – 60Hz
(A low voltage plug-in transformer can be purchased and installed if required)
Peak power consumpon at gate 18W
Electrical class. Class 1
Motor voltage. 24Vdc
Motor current liming. 5A Starng / 3,5A Running
Rated duty cycle. 25% with 220Vac present (See determining your duty cycle on page 7)
Number of operaons on baery reserve
within 24 hours of power failure.
100 (Gate load and baery health dependent. Based on a gate opening of 4m)
Gate speed. 25m/min (Gate load and baery health dependent)
Rated Load. 300N Starng / 240N Running
Operang temperature range. -10 to 50° C (14F to 122F)
An-crushing safety sensing. Yes – Electronic gate proling
Auxiliary supply output. 12Vdc @ 400mA
Built in baery charger. Mulple stage auto-calibrang (350mA peak)
Receiver format. ET BLU MIX ® Backward compable with ET BLUE (Rolling code)
Receiver frequency. 433.92MHz
Receiver channels. 4CH (BT, PED, Aux relay, Holiday lock-out)
Receiver memory capacity. 32 users
All users can be allowed control of all channels. Yes
Ingress protecon. IPX4