135
Rangeofvalues:0000...9999h
OT:Expiredtotaloperationtime.Anoffsetcanbespecified.
Rangeofvalues:00000...99999h
Q 0:
When"R"isselected:
Q=1,ifMN=0;
Q=0,ifR=1orRal=1
When"R+En"isselected:
Q=1,ifMN=0;
Q=0,ifR=1orRal=1orEn=0.
Output Q Theoutputissetwhenthetime-to-goMN=0.Theoutputis
reset:
When"Q 0:R+En",if
R=1orRal=1orEn=0
When"Q 0:R",
ifR=1orRal=1.
Timingdiagram
MI=Configuredtimeinterval
MN=Time-to-go
OT=Totaltimeexpiredsincethelast1signalattheRalinput
Thesevaluesareprincipallyheldretentive!
Parameter
ThemaintenanceintervalMIcanbeprovidedbytheactualvalueofanotheralready-programmed
function:
Analogcomparator:Ax Ay