17
MECHANICAL
Cutout Dimensions: 3.62 W x 1.77 H (92mm x 45mm) DIN standard
Outline Dimensions: 4.04 W x 2.19 H x 3.87 D (103mm x 56mm x 98mm)
3.60 (92mm) maximum depth in panel
Enclosure: Plastic with polyester front label
Connectors: Up to five de-pluggable terminal blocks
INPUT POWER
AC Powered Models (57701-4XX)
Input Power: 85-265 VAC, 47-63 Hz, 20 VA
External Fuse: 0.2A, 250 VAC, Time Delay (T200mA, 250V)
Isolation Dielectric Strength: 2300 VAC
DC Powered Models (57700-4XX)
Input Power: 9-30 VDC, 12 VA
External Fuse: 2.0A, 50 VDC, Time Delay (T2A, 50V)
Reverse Voltage Protection: Yes
Isolation Dielectric Strength: 2300 VAC to signal inputs and relays, 500 VAC
to RS485 and analog outputs
HUMAN INTERFACE
Display: +/- 4 full digits
Type: .56 high, seven segment, red LED
Update Time: 0.4 seconds
Alarm: Flashing display
Indicator: One red LED program/calibration indicator
with max./min. capture and hold
DATA RETENTION
Memory Type: EEPROM, no batteries required
Duration: 100 years
SIGNAL INPUT
DC Voltage Models (5770X-40X)
Range: +/- 199.9 mVDC, +/- 1.999 VDC, +/- 19.99 VDC, +/- 199.9 VDC,
DIP Switch Selectable
Impedance: 1 M W (ohms)
Overrange: 750 VDC/530 VAC except 220 VDC/AC on 199.9 mV range
Accuracy: +/- 0.1% of reading, +/- 0.03% FS, +/- 0.5 digit, and +/- 80 PPM/°C
SPECIFICATIONS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton Durant Eclipse 5770 45 Series and is the answer not in the manual?

Eaton Durant Eclipse 5770 45 Series Specifications

General IconGeneral
BrandEaton
ModelDurant Eclipse 5770 45 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals