-8-
START-S1XL
Operating Guide
1° ch TX OPEN-STOP-CLOSE-STOP...
2° ch TX CLOSE-STOP-CLOSE-STOP...
11 - 14 same as 1st ch TX
11 - 12 ALT button NC makealinkifnotused
11 - 13 Anemometer it inverts and stop
thecontrolunitfor3min.
11 - 15 makealinkifnotused
1° ch TX OPEN-STOP-OPEN-STOP...
2° ch TX CLOSE-STOP-CLOSE-STOP...
11 - 14 same as 1st ch TX
11 - 12 same as 2nd ch TX
11 - 13 Anemometer it inverts and stop
thecontrolunitfor3min.
11 - 15 makealinkifnotused
***
The automatic reclosing
is not available
***
The automatic reclosing
is not available
ON
2
1
43
ON
2
1
43
ON
2
1
43
ON
2
1
43
AN program:
AN-1 program:
1° ch TX OPEN “ Man Present”
2° ch TX CLOSE “Man Present”
11 - 14 same as 1st ch TX
11 - 12 same as 2nd ch TX
11 - 13 Ifthephoto-cellhastheManPresentversion don’t need to make a link
11 - 15 makealinkifnotused
***
In questa versione non
è disponibile la chiusura
automatica!
UP program: “Man present” function
DIP 3-B ON
DIP 4-B OFF
low wind speed
(more sensitive)
DIP 4-B ON
high wind speed
(low sensitive)
DIP A DIP B
DIP 3-B OFF
DIP 4-B OFF
low wind speed
(more sensitive)
DIP 4-B ON
high wind speed
(low sensitive)
DIP A DIP B
It ‘should be used, in combination with the central START-S1XL
set mode AN or AN-1, an anemometer of the type “1 pulse per revolution”
!