36
Engine
Perform the following steps to protect the cylinder, piston ring, etc.
from corrosion.
1. Remove the spark plug, pour about one tablespoon of SAE 10W-30
into the spark plug hole and reinstall the spark plug. Recoil start the
engine by turning over several times (with 4 in 1 switch knob o󰀨) to
coat the cylinder walls with oil.
2. Pull the recoil starter until you feel compression, then stop pulling.
(This prevents the cylinder and valves from rusting).
3. Clean exterior of the generator. Store the generator in a dry,
well-ventilated place, with the cover placed over it (cover sold
separately).
TROUBLESHOOTING
ENGINE WON’T START
1. Fuel systems
No fuel supplied to combustion chamber.
No fuel in tank…Supply fuel.
Fuel in tank….Fuel tank cap and fuel knob to “ON”
Clogged fuel lter …. Clean fuel lter.
Clogged carburetor…. Clean carburetor.
2. Engine oil system Insu󰀩cient
Oil level is low…. Add engine oil.
3. Electrical systems
Put the 3 in 1 switch to “on” and pull the recoil starter … Poor
spark.
Spark plug dirty with carbon or wet … Remove carbon or wipe
spark plug dry.
Faulty ignition system … consult our company authorized dealer.