37
GENERATOR WON’T PRODUCE POWER
Safety device (DC protector) to “OFF”, Press the DC protector to “ON”.
The AC pilot light (Green) goes o󰀨 …. Stop the engine, then restart.
SPECIFICATIONS
SPECIFICATIONS
MODEL NUMBER EGi-3600LN
Generator
Type Silent inverter
Rated frequency (Hz) 50
Rated voltage (V) 240
Rated output power (kW) 1
Power factor 3.0
AC output quality ISO8528 G2
Charging voltage (DC) (V) 12
Charging current (DC) (A) 8.3
Overload protect (DC) Non-fuse protector
Engine
Engine R210-i
Engine type
Single cylinder,
4-Stroke, forced air
cooling, OHV
Displacement (cc) 212
Fuel type Unleaded gasoline
Fuel tank capacity (L) 9.0
Oil capacity (L) 0.6
Spark plug model No. F6RTC
Valve clearance intake/exhaust 0.05 ~ 0.10
Starting mode Recoil Electric
Generator
set
Length×Width×Height (mm)
643×480×498
Net weight (kg)
46
Spark Arrester Equipped* Yes
* If a spark arrester is required it must meet the specications and performance
requirements of local, state, and federal laws and regulations. A spark arrester is
available from authorized servicing dealers.