CONFIGURING THE HVAC
SETTINGS
The rst step after installing the EMS Si is to
congure the settings for the various devices
(such as a furnace or air conditioner) that are
being connected.
Equipment
The Equipment settings let you congure the
devices connected to the thermostat.
Heat Pump
This section lets you congure a heat pump with
up to 2 heat/2 cool stages plus an auxiliary heat
source.
Geothermal heat pump Select Yes if you are
using a geothermal heat pump. This helps the
thermostat determine optimum performance
and default settings. If you select No, the
system will optimize the settings for an air-to-
air heat pump.
OB energize on cool If you choose Yes, the
reversing valve output (O/B terminal) will
activate when there is a call for cooling. If you
select No, the relay will activate when there is
call for heat.
Min Cycle O Time Congures the minimum
compressor o time between cycles (240 to
900 seconds).
Min Outdoor Temp Disables the compressor
when the outside air temperature reaches the
congured minimum setting. This performs
two functions. It prevents the compressor
To congure the
equipment settings:
From the Home screen,
press MENU.
Select Settings ▶
Installation Settings.
Select Equipment.
Congure the devices
connected to the EMS Si.