Adding Generator Engine Oil
There is no engine oil in the generator when delivered from the factory. Do not start the generator
until it has been properly lled with engine oil. When adding engine oil, do not tilt the generator to
prevent damage from excessive oil.
Place the generator on a level surface. Use the provided screwdriver to loosen the bolts of the maintenance cover,
and then remove it. Remove the lid and oil dipstick. Use the provided funnel to add the recommended type and
amount of engine oil. Then, reinstall the lid, oil dipstick, and maintenance cover, and make sure they are fully
tightened.
Connecting Internal Rechargeable Battery
To start the generator using the Electric Start
Switch, connect the internal rechargeable
battery first.
Open the protective cover of the Internal
Rechargeable Battery port. Connect the
positive and the negative wires of the battery
respectively.
Recommended engine oil: SAE SJ 10W-40
Recommended engine oil grade: API Grade SJ or higher
Oil capacity: 550 ml / 0.581 quarts
1 2
Remove the maintenance cover. .
3
Connect the battery