EN
| 16
Gasoline
1. Turn off all the connected electrical equipment, and then disconnect it from
the generator.
2. Situations:
a. For temporary generator shutdown: the procedure is the same as for fuel.
b. For prolonged generator shutdown: Turn off the cylinder valve and wait
until LPG in the generator is fully consumed. The generator will shut down
automatically.
3. Turn the Engine Switch to “OFF” to power off the generator.
LPG
Shutdown
In case of emergency, turn the Engine Switch to OFF position to power off the generator. Under normal
circumstances, please follow the procedure below.
Power AC Devices
Switch off all electrical equipment before inserting plugs.
Make sure that all electrical equipment including wires and plugs are in good condition before
being connected to the generator, and conrm that all loads carried by the generator are within
the rated load range and that the load current is within the rated current range.
Note: Make sure that the generator is grounded. If any electrical equipment needs to be grounded,
the generator must also be grounded.
1. Start the generator.
2. Connect the electrical equipment into the AC Output Socket of the generator, then check if the on-screen AC
output port icon is illuminated.
3. Switch on the electrical equipment.
Note:
When the generator is in operation, the AC output can be turned on / off via the EcoFlow app.
If the output reaches or exceeds 50% of the rated level of the generator, you can switch to high performance
mode via the EcoFlow app.
If the generator is powering multiple electrical equipment, turn on those equipment sequentially based on their
power loads.
1. Switch off all connected loads and disconnect them from the generator.
2. There are 4 methods to shutdown the generator:
a. Using the Engine Switch: Turn the Engine Switch to “OFF”.
b. Using the Electric Start button: Press and hold the Electric Start button for 2
seconds.
c. Automatic shutdown: The generator will automatically shut down when the
DC charging is completed. For details, refer to "Charge DC Batteries" (Page
17).
Note: The generator will automatically shut down after 10 minutes to
conserve fuel if both AC and DC output ports are idle.
d. App shutdown: For details, refer to "EcoFlow App" (Page 18) to download
the app.
3. Wait until the generator is completely cooled down, then turn the Engine
Switch to “OFF” to power off the generator.