High viscosity products (maximum metering capacity: 15 l/h)
Set the jumper for capacity
Ä
Chapter 4.1.2 ‘Pump module’ on page 22, pos. J2) if you
use: High viscosity products (max. 1100 mPas) .
The longer suction stroke will take a reduced metering capacity.
Jumper Setting Metering Volume Setting - Potentiometer Setting
Jumper left side
Minimum Maximum
Metering capacity:
Infinitely variable from … up to … [l/h]
1 15
Suction stroke:
constantly [sec]
0,225
Pressure stroke:
Infinitely variable from … up to … [l/h]
6,4 0,18
Number of Strokes:
Infinitely variable from … up to … [l/h]
9 135
Max. Metering counterpressure:
[MPas (bar)]
0,2 (2)
Reduced metering rate (maximum metering capacity: 2.6 l/h)
If you are removing the jumper for capacity (
Ä
Chapter 4.1.2 ‘Pump module’ on page 22,
Pos. J2) the maximum pump metering rate will reduced if you are metering capacities
lower than 2.6 l/h..
The metering capacity can set precise at the potentiometer (
Ä
Chapter 6.1.1 ‘Setting the
flow rate’ on page 33) between 0.1 (min.) and 2.6 l/h (max.).
The longer suction stroke in this setting allow the metering from: lower viscosity products
and also high viscosity products.
Jumper Setting Metering Volume Setting - Potentiometer Setting
Without Jumper
Minimum Maximum
Metering capacity:
Infinitely variable from … up to … [l/h]
0,1 2,6
Suction stroke:
constantly [sec]
0,225
Pressure stroke:
Infinitely variable from … up to … [l/h]
66,4 2
Number of Strokes:
Infinitely variable from … up to … [l/h]
0,9 27
Max. Metering counterpressure:
[MPas (bar)]
0,2 (2)
Start-up Operations
32Rev. 5-06.2018