High viscosity products (maximum metering capacity: 15 l/h)
Set the jumper for capacity
Ä
Chapter 4.1.2 ‘Pump module’ on page 22, pos. J2) if you
use: High viscosity products (max. 1100 mPas) .
The longer suction stroke will take a reduced metering capacity.
Jumper Setting Metering Volume Setting - Potentiometer Setting
Jumper left side
Minimum Maximum
Metering capacity:
Infinitely variable from … up to … [l/h]
1 15
Suction stroke:
constantly [sec]
0,225
Pressure stroke:
Infinitely variable from … up to … [l/h]
6,4 0,18
Number of Strokes:
Infinitely variable from … up to … [l/h]
9 135
Max. Metering counterpressure:
[MPas (bar)]
0,2 (2)
Reduced metering rate (maximum metering capacity: 2.6 l/h)
If you are removing the jumper for capacity (
Ä
Chapter 4.1.2 ‘Pump module’ on page 22,
Pos. J2) the maximum pump metering rate will reduced if you are metering capacities
lower than 2.6 l/h..
The metering capacity can set precise at the potentiometer (
Ä
Chapter 6.1.1 ‘Setting the
flow rate’ on page 33) between 0.1 (min.) and 2.6 l/h (max.).
The longer suction stroke in this setting allow the metering from: lower viscosity products
and also high viscosity products.
Jumper Setting Metering Volume Setting - Potentiometer Setting
Without Jumper
Minimum Maximum
Metering capacity:
Infinitely variable from … up to … [l/h]
0,1 2,6
Suction stroke:
constantly [sec]
0,225
Pressure stroke:
Infinitely variable from … up to … [l/h]
66,4 2
Number of Strokes:
Infinitely variable from … up to … [l/h]
0,9 27
Max. Metering counterpressure:
[MPas (bar)]
0,2 (2)
Start-up Operations
32Rev. 5-06.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecolab Turbo SMART II Series and is the answer not in the manual?

Ecolab Turbo SMART II Series Specifications

General IconGeneral
BrandEcolab
ModelTurbo SMART II Series
CategoryWater Pump
LanguageEnglish

Related product manuals