2205 System Technical and User’s Guide
Document : 0022175 Rev A Page 11
accuracy unless a Network Time Server is utilized. Configuration of the 1pps sync is covered under the
Trigger subsection 5.7.
6.2 Sonar.ini Setting
The following is a typical SONAR configuration file. Different Tri-Frequency combinations will
reference different pulse folders or calibration files, but their naming format will be consistent with the
entries shown below.
;======================================================================
; This file contains settings you can use to customize the sonar data
; acquisition processor.
; SEE SONAR.TXT for documentation
;======================================================================
;======================================================================
; Main / overall settings.
;======================================================================
[Main]
Config = 2205_SBSS_Trifrequency
PulseCalFile=PulseCal_230_540_850.pcf
TimeSyncSource=0
CompressNet=2
;DspSimulator=2
;DiagnosticLogFileLocation=d:\Data
; =========
; Subbottom
; =========
[SUB_SB]
PulseDirectory = ..\2205 DW106\
TriggerInputLine=0
ADCs= 8
DACs= 0
;======================================================================
;Options for SS Low (230kHz) DDPA