Technical data
M518-00-880 Issue A
2Technical data
2.1 General technical data
2.2 Performance data
Table 1 - General technical data
Characteristics CXS / EH1200 CXS / EH2600 Units
Body dimensions length x width x height 1807 x 760 x 1374
1807 x 760 x 1770 (with FA)
1807 x 760 x 1572
1807 x 760 x 1967 (with FA)
mm
Mass (excluding packaging) 705
765 (with FA)
960
1010 (with FA)
kg
Noise level
(at ultimate with a piped exhaust)
< 75 < 75 dBA
Typical vibration level at inlet < 1.5 < 1.5 mm/s
Table 2 - General technical data
Item Description Rating Units
Operating conditions
Intended use Indoor/Outdoor
Ambient temperature range:
Operating -20
*
to 40 °C
Storage -45
*
to 55
*
For operation/storage in ambients below freezing ensure your cooling-water system is suitably protected
against freezing.
°C
Maximum relative humidity: 80% for temperatures up to 31 °C decreasing
linearly to 50% relative humidity at 40 °C
Maximum operating altitude 2000 m
Pollution degree 2 (IEC 61010)
Lubrication
Oil type - EH booster (hydrocarbon) Ultragrade 20
Oil type - CXS pump PFPE Drynert 25/6 (recommended)
Fomblin
®
25/6 (alternative)
Krytox
®
1525 (alternative)
Table 3 - Performance data
Pump
Characteristics
Typical peak pumping
speed
*
*
T3 variants without flame arresters
Typical ultimate
*
Maximum continuous inlet pressure
CXS250 + EH2600 1900 m
3
/h < 0.05 1000
CXS250 + EH1200 950 m
3
/h < 0.05 1000
CXS160 + EH1200 850 m
3
/h < 0.07 1000

Related product manuals