M518-00-880 Issue A
Page 10 © Edwards Limited 2012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
2.3 Loading data
Figure 3 - Foot loads
2.4 Electrical data
Table 4 - Loading data
Load at foot position (kg)
Pump 1234
CXS160/EH1200 161 186 192 166
CXS160/EH1200 FA
*
*
Systems fitted with flame arresters
167 189 217 192
CXS250/EH1200 161 186 192 166
CXS250/EH1200 FA
*
167 189 217 192
CXS250/EH2600 266 217 210 257
CXS250/EH2600 FA
*
261 225 242 282
Table 5 - Electrical data
Characteristics CXS160/EH1200 CXS250/EH1200 CXS250/ EH2600
Dry pump motor rating 7.5kW 7.5kW 7.5kW
Booster motor rating 3kW 3kW 11kW
Current rating (Amps)
(380 - 415 V systems)
17 19 34
Recommended branch circuit fuse (Amps)
(380 - 415 V systems) J Type
25 25 50
Min cable size for 380 - 415 V systems mm
2
(or
corresponding AWG size)
6(10) 6(10) 10(8)