Appendix A1
A540-55-880 Issue D
By default the 4 parameters displayed in the Normal menu are as shown above but these may be changed via the Edit
Display attributes menu, accessed from the SETUP menu.
A1.4.2 Status menu
Press the Status button to enter. Scroll by pressing up/down keys. Press CANCEL to exit back to Normal menu.
If a device is not fitted the associated parameters will not be displayed. Parameters displayed:
A1.4.3 SETUP menu
Press the Setup button to enter. Menu title is shown at the top of the display. Scroll by pressing up/down keys. Press
ENTER to open a sub menu or CANCEL to exit back to Normal menu.
Table A4 - Status menu
Description Typical Display
Serial Number S/N 1234567
Control Holder NONE IN CONTROL
Dry Pump current DP CURRENT 1.1A
Booster current MB CURRENT 1.1A
Green Mode state Green Mode STATE Off
Dry Pump temperature DP TEMP 100C
Booster Temperature MB TEMP 100C
Booster MB End Cover temperature MB E/C TEMP 100C
N
2
Flow Rate N
2
FLOW 44 slm
Dry Pump Power DP POWER 1.1 kW
Booster Power MB POWER 1.1 kW
Dry Pump speed in percent DP SPEED 100 %
Dry Pump speed in Hz DP SPEED 100 Hz
Booster speed in percent MB SPEED 100 %
Booster speed in Hz MB SPEED 100 Hz
Dry Pump Inverter Temperature DP INV TEMP 100C
Booster Inverter Temperature MB INV TEMP 100C
Run Hours RUN HOURS 1000
Number of Pump Starts PUMP STARTS 100
Time to Stop (seconds) TIME TO STOP 900
Active Alarms and Warnings (if present)
Tab l e A5 - S ETU P m enu
Description Display
Commands menu
*
Command Menu…
Display Inverter Fault History menu Inv Fault Hist…
Software Version Display menu S/W Version…
Display Serial Number Serial Num…
Fit Accessory menu
*
Fit Accessory…
Edit IP configuration menu IP Config…