2. Use correct liing equipment aached t
o all liing eyebolts to move the system
near to its nal operang posion.
Note:
The iXM3000 has four e
yebolts. All other pump variants only have one eyebolt.
3. Adjust the levelling feet to make sure that the system is level and is not supported
by the castors. The recommended jacking height is 5 mm. Refer to Figure: Front
view of the system
4. Remove the liing eyebolts and replace them with the liing eyebolt hole plugs
supplied with the system.
5. Make sure that to the emergency stop buon is accessible. Refer to Figure: Front
panel controls. If not, use a disconnect box, refer to Accessories on page 93.