13-22
CONTROL SYSTEM
Revision Y05-01
Service Manual - DNG Series
13.7.1 Dry, SH or RH group excluding P2000 model
Mode : Dry
Temp: Selected desired temp.
Fan: Low (automatically selected by software)
Timer: Any
I FEEL: Any
Control function
Reduce room humidity with minimum Temp. fluctuations by operating in Cool Mode with low speed
IFAN and HE.
(RT - SPT) [
o
c]
+2
+1
0
-1
-2
ON
OFF
ON
OFF
LOW
OFF
ON
OFF
10
20
30
40 50
COMP
& OFAN
HE1
IFAN
HE2
ON
OFF
RV
Time [min]
Notes :
1) HP and Defrost protections are the same as in Cool Mode.
2) HEs are operated according to the room temp., in the same way as in
Heating for RH group .
3) IFAN is operating continuously at low speed.