No. Description Specification Remark
1 Electric Heating Tube 600W/110V 4
2 Temperature-limited unit 65
2
3 Fuse 99
/10A 2
PROTECTION MODES AND INSTRUCTIONS FOR SERVICE ELECTRIC HEATER
This series of conditioners include a great variety of automatic protection modes, some of the protection
modes are listed below:
Mode Operation Conditions Protection from Controlled remedy
Cooling and
Dry
Low outdoor
temperature
Evaporator
freezing up
Stops outdoor fan and compressor when
approaching freezing conditions.
Resumes operation automatically.
High outdoor
temperature (only for
the unit with heat
pump)
Condenser
overheating
Stops compressor automatically when
approaching over heating temperature.
Resumes operation automatically.
Heating Low outdoor
temperature
Condenser
freezing up
Reverses operation from heating to
cooling for short periods to defrost the
condenser.
High indoor or outdoor
temperature
Evaporator
overheating
Stops outdoor fan and compressor
automatically when evaporator
approaching over heating temperature.
Resumes operation automatically.
Instructions for Service Electric Heater
If any damages happened on electric heating tube, temperature-limited unit and fuse, please get professional
technicians to replace with adoption of parts provided by the company.
Heater works only in heating mode when indoor coil temperature is lower than 45 C.
o