Service Manual
51
9.7 Table of pressure and adjustment
Liquied petro-
leum gases
Gas category Inlet pressure
(mbar)
Injector pres-
sure (mbar)
Injector size (⌀
mm)
Air reducing
plate (mm)
Label number May be avail-
able in follow-
ing countries
Butane mixture
/
Propane
mixture
3+ 28-30 /
37
No regulation 2.30 490359201
A = 18
490375623 BE, CH, CY,
CZ, ES, FR,
GB, GR, IE, IT,
LT, LU, LV, PT,
SK, SI
Butane 3B/P 30, 37, 50 28 2.30 490359201
A = 18
490375624 BE, CY, DK,
EE, FI, FR,
GB, HU, IT, LT,
NL, NO, SE,
SI, SK, RO,
HR, TR, BG,
IS, LU, MT, PL,
AT, CH, DE,
SK
Propane 3P 30, 37, 50 28 2.40 490359201
A = 18
490375625 FI, NL, RO,
BE, CH, CZ,
IE, IT, ES, FR,
GR, GB, HR,
LT, NL, PL, PT,
SI, SK, AT, CH,
DE, NL, LU,
SK
Natural gas Gas category Inlet pressure
(mbar)
Injector pres-
sure (mbar)
Injector size (⌀
mm)
Air reducing
plate (mm)
Label number May be avail-
able in follow-
ing countries
2H, 2E 20 8 4.00 490359201
A = 18
Default AT, BG, CZ,
DK, EE, FI,
GR, HR, HU,
IS, IE, IT, LV,
LT, NO, PT,
RO, SK, SI,
ES, SE, CH,
TR, GB, DE,
PL, LU
2E+ 20 / 25 No regulation 3.30 490359203
A = 29
490375621 BE, FR
2LL, 2L 20, 25 12 4.00 490359203
A = 29
490375622 NL, DE