Service Manual
49
9.5 Replacement of ignition cable
Shut off the manual gas valve.
Disconnect the power to the machine.
Demount the two rear panels.
fig.7215E
Disconnect the ignition cable.
Demount the ignition electrode.
fig.7279
Mount the new ignition electrode and connect the ignition cable.
Adjusting ignition electrode
The distance from the ignition electrode to the gas burner must be 5 mm. The spark gap must be 3 mm.