Service Manual
When a machine with liquid petroleum gases shall be installed or used on high altitude (2001 feet and higher) the kit
“kit high altitude LPG” must be installed.
For kit No. please refer to the spare parts list.
9.8 Test run
Loosen the measuring branch screw (2) 1/4 turn; connect a manometer to the measuring branch.
Select a program with heat.
Start the machine.
Check the nozzle pressure, see “Table of pressure and adjustment”.
If necessary adjust the regulator setting screw (4) behind the cover screw (3). Replace the cover screw (3) if
removed.
Check that the gas is burning evenly.
fig.7120