Procedure for use
4758 A
Calibration mode/normal mode
To gain access to the calibration switch in the
scale unit, the top panel has to be taken off. Re-
move the four screws on the scale unit cover. Then
the calibration switch can be switched between
normal mode ”ON” and calibration mode ”CAL”.
ON (normal)
4795
4791
Press SELECT.
Restore the calibra
-
tion switch to normal
mode.
Press SELECT.












For machines with weighing equipment installed only!
CAL (calibration)
Calibration
switch
Scale unit