When replacing the filter, also change the hydraulic fluid. See “11.4.6. Refilling the hydraulic fluid”,
page 58.
The filter cartridge includes a central filter which is screwed into the cartridge fixture.
Unscrew the filter cartridge by turning it counter-clockwise.
Completely unscrew the cartridge and allow the remaining fluid to flow through the funnel. -Wipe
away the fluid and also clean the filter cartridge fixture.
New filter cartridges are always obtainable from your authorised ELIET dealer. Order code: BH
280 212 010
Soak the new filter's gasket in hydraulic fluid to moisten it.
Now screw the new filter cartridge onto the fixture by hand.
Once the cartridge has been attached to the fixture, make a further
3/4
turn to ensure that the
seal is tight.
Fill the hydraulic oil tank and replace the cap.
Start the engine and engage the starter to circulate the fluid and warm up the machine.
Ensure that the entire fluid circuit is well sealed (no leaks)
Clean any fluid that has spilled with paper, and dispose of wet cloths as chemical waste.
The filter cartridge will also be disposed of as chemical waste.