EasyManua.ls Logo

Eliwell RGF 312 - E Lectrical Connections

Eliwell RGF 312
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RGF 300
15/53
Mains surveillance
Continually checks presence of the three mains phases; when one phase
is absent, it stops the appliance and switches on the “phase absent” alarm
signal LED (
AC LINE ALARM
)
EMC integrated
mains filter
According to
EN 55011
(
CEI 110-6
) Class
B
:
ISM
appliances directly connected to low voltage power mains
P
ROTECTIONS
Overvoltage protection According to
EN 61000-4-5
: overvoltage Category
II
(
4 KV
)
RGF 312 286 x 201 x 130 mm 4.0 kg
RGF 320 351 x 237 x 181 mm 5.5 kg
RGF 325 351 x 237 x 201 mm 8.0 kg
RGF 340 416 x 318 x 178 mm 11.0 kg
Dimensions and Weight
RGF 360 460 x 318 x 220 mm
17.0 kg
Materials
GW-Plast 120°C
and black anodised aluminium
Degree of protection
IP 55
Environmental pollution Strong pollution
C
ASE
Fire resistance Category
D
Case Class
I
(use of earthed protection cable)
I
NSULATION
Control circuits
4000V
between control input and mains voltage components
Working
-20 T 50
(from –20°C to + 50°C)
T
EMPERATURE
Storing
-30 T 85
(from –30°C to + 85°C)
H
UMIDITY
RH < 85%
I
NSTALLATION
Vertical wall-mounting only, with
N° 4
6
mm. holes (RGF350 with
N° 4
8
slotted holes)
SIGNAL
Trailing cable with rated cross section
1.5 sq mm / 22-14 AWG Cu
RGF 312
Trailing cable with rated cross section
2.5 sq mm / 20-12 AWG Cu
RGF 320
Trailing cable with rated cross section
4.0 sq mm/ 24-10 AWG Cu
RGF 325
Trailing cable with rated cross section
10 sq mm / 20-6 AWG Cu
RGF 340
Trailing cable with rated cross section
10 sq mm / 20-6 AWG Cu
E
LECTRICAL
CONNECTIONS
POWER
RGF 360
Trailing cable with rated cross section
10 sq mm / 20-6 AWG Cu
89/392/EEC
Directive
73/23/EEC
Directive
(93/68)
CEI-EN 60204-1
: “ Safety of machinery”
EN 50081-2
Generic standard for industrial environment emission
EN 50082-2
Generic standard for industrial environment immunity
EN 55011
class
B
, for radiated disturbance
EN 55011
class
B
, for conducted disturbance
ENV 50140
(
IEC 801-3
) for susceptibility (on the supply)
ENV 50141
for conducted susceptibility on the signal lines
IEC 801-4
for fast transients (burst / high-frequency disturbance)
T
ECHNICAL
STANDARDS
89/336/EEC
Directive
IEC 801-2
for electrostatic discharge (
ESD
)
Table 3

Related product manuals