EasyManuals Logo

ELTEX MES1000 User Manual

ELTEX MES1000
231 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #165 background imageLoading...
Page #165 background image
MES1000, MES2000 Ethernet Switches 165
Destination to Source Latency one way Min/Avg/Max: 0/0/0 ms
Destination to Source Latency one way Sum: 0 ms
Jitter values:
Source to Destination positive jitter Min/Avg/Max: 1/2/20 ms
Source to Destination positive jitter Num/Sum: 272/706 ms
Source to Destination negative jitter Min/Avg/Max: 2/3/6 ms
Source to Destination negative jitter Num/Sum: 91/311 ms
Destination to Source positive jitter Min/Avg/Max: 1/2/17 ms
Destination to Source positive jitter Num/Sum: 96/241 ms
Destination to Source negative jitter Min/Avg/Max: 1/1/6 ms
Destination to Source negative jitter Num/Sum: 29/46 ms
Packet Loss values:
Out Of Sequence: 0
Number of successes: 91
Number of failures: 0
Operations failed due to TimeOut/Unable Send/Bad Reply: 0/0/0
Operations failed due to Unreachable Net/Host/Port/Prot: 0/0/0/0
Operations failed due to Exceeded TTL/Time of reassembly: 0/0
Packet unidirectional transit statistics may be empty because of the missing time
synchronization on devices and generation of invalid values.
where
Latest operation return code: completion code of the last executed operation:
OK: previous operation has been completed successfully.
Failed: measurement attempt has failed.
Latest latency value: the latest successfully measured bidirectional latency value.
Latency two-way values: bidirectional packet transit time measurement statistics.
Latency one-way values: unidirectional packet transit time measurement statistics:
SD: from source to destination (source-to-destination).
DS: from destination to source (destination-to-source).
Jitter values: unidirectional jitter measurement statistics. Positive and negative jitter values
are recognized separately in each direction.
Out Of Sequence: number of packets returned out of sequence.
Number of successes: number of successfully completed operations.
Number of failures: number of failed operations.
Failed operations: counters that show the number of measurement operations completed
with the respective error code.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ELTEX MES1000 and is the answer not in the manual?

ELTEX MES1000 Specifications

General IconGeneral
BrandELTEX
ModelMES1000
CategorySwitch
LanguageEnglish

Related product manuals