Instruction Manual V 2.30 6 / 36
1.2.
Before Use
Prior to power-on the equipment
- Before putting the instrument into operation, please check the equipment you have received for damage due to transporta-
tion. Check the single boxes as well as the generator itself for mechanical damage. In case of damages, please contact
the manufacturer before switching on the unit.
Damage due to transportation
- Prior to applying power, check if the selected supply voltage complies with the mains:
115V/230V ??
- Equipment of security class I which is supplied by an auto-transformer may be considered as follows:
If the equipment is powered by an auto-transformer, with a primary voltage higher than the secondary voltage, be sure that
the low-voltage end of the secondary part of the auto-transformer is connected with the neutral of the primary side.
Equipment of security class I with removable neutral or with mains plug:
It is only permitted to insert the mains plug in a mains socket with protective earth connector. It is not allowed to interrupt or
disconnect the protective earth connection.
Performance of measurements
- Each interruption or disconnection of the protective earth connection inside or outside the equipment may lead to a
dangerous situation. Intentional interruption is prohibited.
- Interconnections between such equipment or to others, e.g. for remote control by personal computer, may be done with
cables recommended or delivered by the manufacturer.
1.3.
Maintenance, Adjustments, Exchange of Parts
The generator does not include any parts or components needing special maintenance.
Electrical maintenance should only be performed by experienced, specially instructed technicians.
Generally, standard maintenance requires periodic cleaning of the instrument and verification and calibrations of the speci-
fied pulse parameters only.
ATTENTION
Only trained technicians are allowed to perform
service or maintenance work on these instruments.
- When removing the housing cover or other parts of the equipment, high
voltage parts may become exposed. High voltage and high current are potentially lethal.
- The generator includes high voltage capacitors, which may retain their charge. High voltage High energy
- For service, repair, adjustment, or replacement, the generator covers have to be removed and the generator must be
disconnected from all power mains supplies.
- The user is not allowed to independently change or modify any EM TEST generator. For service and repair, only original
EM TEST parts and components must be used. EM TEST is not responsible for any accident or injury incurred through the
use of other parts or components.
- If maintenance or service work is necessary, it must be performed only by experts who are familiar with the existing
danger.
- It has to be assured that only fuses of recommended type and nominal current are used for replacement. It is not per-
missible to use repaired fuses.

Other manuals for EM TEST dito

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EM TEST dito and is the answer not in the manual?

EM TEST dito Specifications

General IconGeneral
BrandEM TEST
Modeldito
CategoryTest Equipment
LanguageEnglish

Related product manuals