Introduction
Parameter
x.00
Parameter
description format
Keypad and
display
Serial
communications
CT Modbus
RTU
PLC Ladder
programming
CTSoft Menu 0
Advanced parameter
descriptions
Menu 1
Commander SK Advanced User Guide 45
Issue Number: 9 www.controltechniques.com
Indicates the preset currently being selected. If Pr 1.49 = 1 or 2 then a value of 1 indicates that one of the analog references is being selected.
Selects the value of the keypad reference on power-up.
Value Display Function
0 0 keypad reference is zero
1 LASt keypad reference is the last used value
2 PrS1 keypad reference is copied from Preset speed 1 (Pr 1.21)
1.50 Preset reference selected indicator
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111 1
Range 1 to 8
Update rate 5ms
1.51 Power-up keypad reference {27}
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
1 111
Range 0(zero), LASt(1), PrS1(2)
Default 0
Update rate N/A