Damcos LPU: Troubleshooting Guide LPU Service Manual
February 2017 SM 8000-100-01 Ed 04
57
LPU-D not maintaining pressure on actuator
Pressure drops only on 1 port
Leakage in check valves for DPCV or release valve.
Change check valves for DPCV.
A leakage in actuator might give pressure drop on only one port.
Replace the seal set in actuator with a new one.
Pressure drops on both ports
Leakage in bypass valve (actuator) or actuator.
Check bypass valve, possibly replace release valve (see “Replace release valve in LPU” on
page 99).
Check actuator.