Service Manual Damcos LPU: Refill of Oil in LPU
SM 8000-100-01 Ed 04 February 2017
90
LPU-S mounted on BRCF oil filling with hand pump
1. Connect hand pump pressure hose to quick connection T.
2. Dismount breather valve or upper-most plug in LPU tank.
3. Apply oil to T-port until tank is full (oil is just about to pour out of tank).
4. Remount breather valve/plug in LPU tank.
5. Dismount breather valve or upper-most plug at top of BRCF.
6. Apply oil to T-port until oil is just about to pour out of BRCF spring chamber.
7. Remount breather valve/plug in BRCF.
8. Disconnect hand pump.
9. Open/close actuator a few times by remote control.
Note! For LPU-S do not operate the directional slide of hand pump to release pressure. The oil
inside actuator will flow back to hand pump, but oil will not flow from hand pump to tank
line of actuator. Thus oil will be emptied out of LPU if LPU-S is closed by operating the
directional slide of hand pump.
10.Resume step 1 to 8 until oil level is stable at correct level.
breather valve
quick connection B
(OPEN)
quick connection T
by-pass valve