Service Manual Damcos LPU: Replace Pump in LPU
SM 8000-100-01 Ed 04 February 2017
94
7. Oil the new stator and place it with slot for pin in
same direction as slot in valve block
Be sure the small pin is in place on stator!
8. Turn in the stator. When stator is turned to correct
rotational position press it down to same level as
mounting tool.
9. Check the height of stator.
Stator is pressed until extension above valve block
surface is 19 mm. This should correlate with the
height of mounting tool as of point 8.
10.Check suction pipe filter for contamination. If nec-
essary clean the filter.
Mount the suction pipe.
.
11.Rotor with pistons is placed on stator or in LPU
block depending on mounting direction of LPU.
Rotor coupling must be placed in same direction as
corresponding slot in motor shaft.
Replace Pump in LPU
It is essential
that the height
of stator is
exactly 19 mm!