3410 Series Gas Ultrasonic Meters Operations Manual Section 6: Archive logs
3-9000-777 Rev E January 2018
Audit log 101
Table 6-11 Audit log expansion correction group monitored data points
Expansion correction data group Data point
EnableExpCorrPress
EnableExpCorrTemp
LinearExpansionCoef
PipeOutsideDiameter
PoissonsRatio
RefPressExpCoef
RefTempLinearExpCoef
YoungsModulus
Table 6-12 Audit log flow analysis group monitored data points
Flow analysis data group Data point
AbnormalProfileDetectionLmt
BlockageCrossFlowLmt
BlockageSymmetryLmt
BlockageTurbulenceLmtA
BlockageTurbulenceLmtB
BlockageTurbulenceLmtC
BlockageTurbulenceLmtD
ContinuousFlowAnalysisKey
FlowAnalysisHighFlowLmt
FlowAnalysisLowFlowLmt
IsAbnormalProfileDetectionEnabled
IsBlockageDetectionEnabled
IsBoreBuildupDetectionEnabled
IsLiquidDetectionEnabled
IsReverseFlowDetectionEnabled
LiquidDetectionSDevCrossFlowLmt
LiquidDetectionSDevProfileFactorLmt
LiquidDetectionSDevSymmetryLmt
ReverseFlowDetectionZeroCut
ReverseFlowVolLmt

Table of Contents