3410 Series Gas Ultrasonic Meters Operations Manual Section 7: Tools commands
3-9000-777 Rev D June 2016
Baseline viewer 133
7.6 Baseline viewer
Use the Baseline viewer to monitor the meter’s flow direction and flow characteristics including:
Flow Velocity
Profile Factor
Swirl Angle
Symmetry
Cross-flow
Path Turbulences
Access the Baseline viewer from the
Meter|Monitor (Detailed) dialog while connected to your
meter.
Note: You must have a valid Continuous Flow Analysis key to enable this feature. See
Section 3.1.1 for instructions about obtaining the Continuous Flow Analysis key and Section
5.13.1 to configure the baseline parameters for your meter using the
Tools|Set Baseline Wizard
menu.
Figure 7-7 Baseline viewer
The Baseline viewer indicates the current flow direction, forward or reverse, and gauges display
the flow characteristics of the meter. The Baseline viewer dialog displays a horizontal “green
zone” that indicates the expected value range. As an example, Figure 7-7 depicts out-of-range
values for turbulence on all four chords.