Conversion factors per units of measurement (continued)Table A-1:
Conversion factors Unit of measurement
6.289811 bbl/m 3
10 -3 Pa•s/cPoise
1.488 Pa•s/(lb/(ft•s))
A.2 K-Factor and inverse K-Factor conversions
Frequency volumetric flow rate K-Factor Equation A-1:
KFactor =
FreqQ
FullScale
(
MaxFreq
)
3600s § h r
(
*
)
and
Frequency volumetric flow rate inverse K-Factor Equation A-2:
InvKFactor =
(
MaxFreq
)
(
3600s § hr
)
(
*
)
FreqQ
FullScale
where
KFactor
frequency “K-Factor” (pulses/volume**) (Freq1KFactor andFreq2KFactor)
InvKFactor
frequency “Inverse K-Factor” (volume**/pulse) (Freq1InvKFactor and
Freq2InvKFactor)
FreqQ
FullScale
frequency full-scale volumetric flow rate (volume**/time unit*)
(Freq1FullScaleVolFlowRate and Freq2FullScaleVolFlowRate)
MaxFreq
maximum frequency (Hz = pulses/time unit*) (Freq1MaxFrequency and
Freq2MaxFrequency)
(*) TimeUnit
time conversion factor depends on the VolFlowRate Time Unit data point:
volume/second = 1 s/s
volume/minute = 60 s/m
volume/hour = 3600 s/h
volume/day = 86400 s/d
(**) Volume
where the volume is selected via data points:
Units System
VolUnitUS
- gallons
- barrels
Conversion factors