Owner and operator manual Section 4: Orifice plate installation and removal instructions
3-9008-001 Rev M January 2015
“Quick change” procedure 67
32. Once the Orifice Plate Carrier (8DM or 8DMC) is positioned in the Body (4), turn the
Slide Valve Shaft (5) using the Operating Wrench (2) into the CLOSED position.
Step 32 Step 33
33. Close the Equalizer Valve (1).
PRESSURIZED FLUID HAZARD
When opening the bleeder valve (10B) or venting the Top (14) thru the bleeder valve (10B),
direct the released pressurized fluid and/or gas to safe area away from any individual in
accordance with local environment regulations.
The bleeder valve (10B) releases pressurized fluid that may cause contamination and/or
accumulation of volatile gas mixtures. Failure to do so may cause serious injury or death.