82 “Extended time” procedure
Section 4: Orifice plate installation and removal instructions Owner and operator manual
January 2015 3-9008-001 Rev M
Step 20 Step 21
21. Immediately install a new Sealing Bar Gasket (9A, 9A-HP or 9CF) on the Top (14) along
with the Sealing Bar (9 or 9HP) and the Clamping Bar (12 or 12HP).
22. Tighten each Clamping Bar Screw (11) located on the Clamping Bar (12 or 12HP) to the
torque recommended in this manual (refer to Section 5.3: Torque information).
EXPLOSION HAZARD
Follow the instructions in this manual to assure that the Sealing Bar Gasket (9A, 9A-HP or 9CF),
the Sealing Bar (9 or 9HP) and the Clamping Bar (12 or 12HP) provide a pressure barrier
between the line pressure and the atmosphere.
Failure to properly install these parts may result in explosive separation of components resulting
in serious injury or death.