1592015610 User manual IC200D EVO GB rel1.0 10.11.2015_rev10 IC200D 162/192
Max. offset of the Defrost dinamic set point
Outside temperature set point of the Defrost dinamic set point
Outside temperature differential of the Defrost dinamic set point
Domestic hot water regulation mode
Recovery modes
0 = not enabled
1 = 2 indipendent circuit
2 = both the circuit in parallel
Delay time delay with step forced off
Delay time delay with step forced off after the recovery valve activation
Minimum interval time between the end and the beginning of the next
recovery
Temperature setpoint to disable the recovery
Temperature differential to restore the recovery
Maximum time with recovery disabled (if temperature/pressure within rC6-
rC7)
Minimum value of the heat recovery set point
Maximum value of the heat recovery set point
Differential heat recovery
Domestic hot water regulation mode
0= not enabled
1=valves in water circuit
2=valves in gas circuit
Domestic hot water thermoregulation priority
0 = heating / cooling
1 = domestic hot water
2 = domestic hot water by digital input
Domestic hot water thermoregulation set point
Domestic hot water thermoregulation band
Minimum value of the domestic hot water set point
Maximum value of the domestic hot water set point
Full loads enabling to reach the domestic hot water set point
Heaters enabling during the domestic hot water thermoregulation
0= not enabled
1= compressors + heaters
2= only heaters
3= only compressors
Operation working time to activate the heaters during the domestic hot
water thermoregulation
Time delay to activate the domestic hot water valve
Reversing cycle delay during domestic hot water thermoregulation
Antilegionella function operating mode
0 = interval time
1= weekly
2= daily