EasyManua.ls Logo

Emerson EL-O-Matic F Series - Page 21

Emerson EL-O-Matic F Series
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
5. Install the actuator to the bracket. Tighten all bolts and apply the correct torque
(refer to Table 8).
Table 8. Bottom flange torque values
Actuator Size ISO Pattern
Torque (Nm) Torque (lbf.ft)
Thread Min. Max. Thread Min. Max.
12 F04 M6 4.5 5 10-24UNC 3.3 3.7
25
F03 inner pattern M5 2.0 3.0 10-24UNC 1.5 2.2
F05 outer pattern M6 4.5 5.0 1/4"-20 3.3 3.7
40, 65, 100
F05 inner pattern M6 4.5 5.0 1/4"-20 3.3 3.7
F07 outer pattern M8 10.5 12.5 5/16"-18 7.7 9.2
150, 200, 350
F07 inner pattern M8 10.5 12.5 5/16"-18 7.7 9.2
F10 outer pattern M10 21.0 24.5 3/8"-16 15.5 18.1
600
F10 inner pattern M10 21.0 24.5 3/8"-16 15.5 18.1
F12 outer pattern M12 34.5 43.0 1/2"-13 25.4 31.7
950
F10 inner pattern M10 21.0 24.5 3/8"-16 15.5 18.1
F14 outer pattern M16 90.0 104.0 5/8"-11 66.4 76.7
1600, 2500
F16 inner pattern M20 170.0 204.0 3/4"-10 125.4 150.5
F25* outer pattern 4x M16 90.0 104.0 4x 5/8"-11 66.4 76.7
4000
F16 inner pattern M20 170.0 204.0 3/4"-10 125.4 150.5
F25 outer pattern 8x M16 90.0 104.0 8x 5/8"-11 66.4 76.7
6. When required, mount or adjust the visual indicator (22).
Figure 12 Indicator mounting
Indicator mounting “In-line”
Indicator mounting “Across Line
Size 12 - 350 Size 600 - 4000
21
21
90°
90°
90°
21
21
Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 7
September 2017
17
Section 4: Installation

Table of Contents

Other manuals for Emerson EL-O-Matic F Series

Related product manuals