EasyManua.ls Logo

Emerson FB1100 - Removing the Front or Rear End Caps

Emerson FB1100
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FB1100 Flow Computer Instruction Manual
D301752X012
November 2023
18 Installation
Figure 2-3. Retaining Clamp in Place
To loosen or tighten the screw, use a 3mm hexagonal wrench. When tightening, torque to
12 in-lbs (1.4 N m).
Figure 2-4. Retaining Clamp and Screw
2.6.2 Removing the Front or Rear End Caps
DANGER
EXPLOSION HAZARD: Never remove end cap(s) in a hazardous location. Removing end
cap(s) in a hazardous location could result in an explosion.
Note
If you need more leverage place a long screwdriver or other appropriate tool across the
two notches in the end cap to act as a pry bar (see Figure 2-5).
Figure 2-5. Removing or Tightening the End Cap with Long Screwdriver
1.
Remove the retaining clamp (if present). (See Section 2.6.1.)
2.
Grasp the end cap (front or rear).

Table of Contents

Other manuals for Emerson FB1100

Related product manuals