FB1100 Flow Computer Instruction Manual
D301752X012
November 2023
Installation 21
Figure 2-9. Transmitter with Coplanar Flange and Optional Flange Adapters
Figure 2-10. Transmitter with Traditional Flange and Optional Flange Adapters
Use the following bolt installation procedure:
1.
Carbon steel bolts do not require lubrication. Stainless steel bolts are factory-coated
with a lubricant to ease installation. Do not apply any additional lubricant when
installing either type of bolt.
2.
Finger-tighten the bolts.
3.
Torque the bolts to the initial torque value using a crossing pattern. See Table 2-3
for initial torque value.
4.
Torque the bolts to the final torque value using the same crossing pattern. See Table
2-3 for final torque value.
5.
Verify that the flange bolts protrude through the sensor module before applying
pressure.
Table 2-3. Torque Values for the Flange and Flange Adapter Bolts
Material
Head markings Initial Torque Final Torque
Carbon
Steel (CS)
300 in. -lbs.
(33.9 N m)
650 in. -lbs.
(73.4 N m)
Stainless
Steel (SST)
150 in. -lbs.
(16.9 N m)
300 in. -lbs.
(33.9 N m)

Table of Contents