FB1100 Flow Computer Instruction Manual
D301752X012
November 2023
26 Installation
Figure 2-15. Housing Rotation Set Screw (1 each side)
Set Screw (one each side)
EXPLOSION HAZARD: Ensure the area in which you perform this operation is non-
hazardous. Performing this operation in a hazardous area could result in an explosion.
1.
Loosen the two housing rotation set screws.
2.
Rotate the housing no more than 180 degrees from its original (as-shipped)
position.
3.
Re-tighten the two housing rotation set screws. Torque to 6 in-lbs. (0.7 N m).