FB2100 Flow Computer Instruction Manual
D301783X012
November 2023
Installation 25
Figure 2-11. Transmitter with Coplanar Flange and Optional Flange Adapters
Figure 2-12. Transmitter with Traditional Flange and Optional Flange Adapters
Use the following bolt installation procedure:
1.
Carbon steel bolts do not require lubrication. Stainless steel bolts are factory-coated
with a lubricant to ease installation. Do not apply any additional lubricant when
installing either type of bolt.
2.
Finger-tighten the bolts.
3.
Torque the bolts to the initial torque value using a crossing pattern. See
41T
Table 2-3
41T
for
initial torque value.
4.
Torque the bolts to the final torque value using the same crossing pattern. See
41T
Table
2-3
41T
for final torque value.
5.
Verify that the flange bolts protrude through the sensor module before applying
pressure.
Table 2-3. Torque Values for the Flange and Flange Adapter Bolts
Carbon Steel
(CS)
300 in. -lbs.
(33.9 N m)
650 in. -lbs.
(73.4 N m)
Stainless Steel
(SST)
150 in. -lbs.
(16.9 N m)
300 in. -lbs.
(33.9 N m