EasyManua.ls Logo

Emerson FB2100 - DI Wiring; Digital Outputs; 3-3. Digital Input Characteristics

Emerson FB2100
126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FB2100 Flow Computer Instruction Manual
D301783X012
November 2023
70 I/O Configuration and Wiring
Table 3-3. Digital input Characteristics
Type
Number Supported
Characteristics
Digital Input
(DI)
0 to 2 as follows under I/O
option 2 only:
1 or 2 non-isolated channels
on CPU board (DI/DO/PI1 and
DI/DO/PI2). Two always
present; you can configure
one, both, or neither as DIs.
Circuit protection
30ms input filtering
Maximum input frequency of
10 Hz
Selectable current source of 66
µA or 2 mA
Either externally driven or
internally driven and pulled to
ground by dry contact
closures or open collector
devices
When a channel is configured
as a DI it cannot be used as a
DO or PI channel
3.3.1 DI Wiring
The diagram below shows how to wire the digital input.
Figure 3-4. Digital Input (DI) Wiring [DI/DO/PI1 & DI/DO/PI2] (I/O Option 2)
1
Dry contact
3.4 Digital Outputs
The FB2100 flow computer with I/O option 1 includes a single digital output. The FB2100
flow computer with I/O option 2 includes two channels you can configure as digital
outputs (DO), digital inputs (DI) or pulse inputs (PI).

Table of Contents