EasyManua.ls Logo

Emerson FB2100 - O-Rings with Flange Adapters

Emerson FB2100
126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FB2100 Flow Computer Instruction Manual
D301783X012
November 2023
26 Installation
Figure 2-13. Proper Bolt Installation
1
Bolt
2
Sensor module
O-rings with Flange Adapters
DANGER
Failure to install proper flange adapter O-rings may cause process leaks, which can
result in death or serious injury. Only use the O-ring that is designed for its specific
flange adapter.
Figure 2-14. O-rings with Flange Adapters
1
Flange
2
O-ring
3
Square PTFE-based profile
4
Round Elastomer profile
1.
Whenever the flange or adapters are removed, visually inspect the O-rings.
2.
Replace the O-rings if there are any signs of damage, such as nicks or cuts.
3.
If the O-rings are replaced, re-torque the flange bolts and alignment screws after
installation to compensate for seating of the O-rings.

Table of Contents