EasyManua.ls Logo

Emerson Micro Motion 1700 - Page 294

Emerson Micro Motion 1700
328 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual Setup menu: MeasurementsFigure D-9:
* Displayed only if Volume Flow Type =
Liquid. Menu numbers are adjusted
as required.
On-Line Menu >
2 Configure >
1 Manual Setup >
2 Measurements
Flow
1 Flow Direction
2 Flow Damping
3 Mass Flow Unit
4 Mass Flow Cutoff
5 Volume Flow Unit *
6 Volume Flow Cutoff *
7 Mass Factor
8 Volume Factor
Density
1 Density Unit
2 Density Damping
3 Density Cutoff *
4 Density Factor
5 Slug Duration
6 Slug Low Limit
7 Slug High Limit
Temperature
1 Temperature Unit
2 Temp Damping
1
2
3
6
Special Units
1 Mass Special Units
2 Volume Special Units
Update Rate
1 Update Rate
2 100 Hz Variable
4
External Pressure/Temperature
1 Pressure
2 Temperature
3 External Polling
GSV
1 Volume Flow Type
2 Gas Ref Density
3 GSV Cutoff
4 GSV Flow Unit
7
8
Pressure
1 Pressure Unit
2 Pressure Compensation
3 Compensation Pressure
4 Flow Cal Pressure
5 Flow Press Factor
6 Dens Press Factor
Temperature
1 Temperature Unit
2 External Temperature
3 Correction Temperature
External Polling
1 Poll Control
2 Ext Dev Tag 1
3 Polled Variable 1
4 Ext Dev Tag 2
5 Polled Variable 2
1
2
3
Using the Field Communicator with the transmitter
286 Micro Motion
®
Model 1700 Transmitters with Analog Outputs

Table of Contents

Other manuals for Emerson Micro Motion 1700

Related product manuals